Product Details:
Trip Time Delay3 sec for UV OV, 5 sec. OL 5 minutes for UL
Over LoadDefault 15 A. User settable by keys.
Output Contact RatingOutput contact rating for AC 25 A at 230 VAC
Power On Delay Time1 minutes
System Supply230 VAC +/- 15%
Over VoltageDefault 260 V .User settable by Keys. 10 V hysteresis between Cutoff Cut in. Auto reset
Under VoltageDefault 180 V User settable by keys. 10 V hysteresis. Auto reset.
Cycle Time240 min.
Restart Delay Time3 minutes
Under LoadDefault 3 A user settable. Make it 0 A to bypass UL protection

Technical Specifications:
Indications1) Healthy: Indicates controller is working healthy.
2) ALARM: when this LED glows it indicates presence fault.
3) AC ON: when this LED glows it shows AC is ON


Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Supply415 VAC(R, Y, B, N), 50Hz
Display16*2 LCD Display for status Faults.
Input3 Phase 415 VAC, 50 Hz (R, Y, B N) (No auxiliary supply).
Terminals1] Separate O/Ps for each AC. 2] Temperature sensor. 3] Alarms relay o/p.
Alarm OP2 Nos. Alarm contacts @ 7Amp A/C.
SensorNTC Temp sensor for room Temp.(Range 0 - 55 deg C)
Output40Amp 3 pole contactor for each A/C (230VAC) for ALARM contact.

Technical Specifications:
Indications1) Healthy indication for controller.
2) A/C ON indication for each A/C.
3) Alarm indication 2 nos: AC Alarm, Fire Alarm.
Front Panel1] 16 char. 2 lines LCD display with backlight.
2] 4 Key keypad for programming.
3] A/C1 ON indication.
4] A/C2 ON indication.
5] Healthy Indication by blinking Green LED.
6] ALARM indication by Red LED.
Sensing1] Inbuilt voltage sensing for Relay.
2] Inbuilt Currant sensing for Relay.
3] Temperature sensing by precise Temp. Sensor.


Alarms/ Protections1] Over voltage protection set point user settable.
2] Under voltage protection set point user settable.
3] SPP voltage protection with disable allows.
4] Unbalance voltage protection set point user settable with disable allow.
5] RP voltage protection with disable allows.
6] Over Load protection set point user settable.
7] Under Load protection set point user settable.
8] Load Unbalance protection set point user settable with disable allows.
9] High/low temperature alarm set point user settable.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
SensorNTC Temp. Sensor for room temp (Range 0 - 55 deg C)
Fire AlarmFire Alarm input from Fire Panel
Indications1) Healthy indication for controller. 2) A/C ON indication for each A/C. 3) Alarm indication 2 no's
Alarm OP2 Nos. Alarm contacts @ 7A 250V AC
SupplySingle phase 230 VAC, 50 Hz.
Display16 X 2 LCD Display for Status Faults.
Output30 Amps. At 250 V AC for A/C Contacts,
Dimensions330 (W) X 220 (H) X 80 (D)

We are offering 2 AC Controller MODEL: TT-2 to our clients.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 3,500 / Piece Get Latest Price

Product Details:
SupplySingle phase 230 VAC, 50 Hz.
Alarm OP2 Nos. Alarm contacts @ 7A 250V AC
SensorNTC Temp. Sensor for room temp ( Range 0 - 55 deg C)
Output30 Amps. At 250 V AC for A/C Contacts,
Dimension330 mm (W) X 220 mm (H) 80 mm (O)
Display16 X 2 LCD Display for status Faults.
Fire AlarmFire Alarm input from Fire Panel

Technical Specifications:
Indications1) Healthy indication for controller.
2) A/C ON indication for each A/C.
3) Alarm indication 2 nos: AC Alarm, Fire Alarm.
Front Panel1) 16 char X 2 lines LCD display with backlight.
2) Key keypad for programming.
3) A/C1 ON indication.
4) A/C2 ON indication.
5) A/C3 ON indication.
6) Healthy Indication by blinking Green LED.
7) ALARM indication by Red LED.
8) FUN,INC,DEC,ENT keys for parameter setting.
Sensing1) Inbuilt Voltage sensing for compressor.
2) Temperature sensing by precise Temp. Sensor.
3) Fire Alarm sensing.
Terminals1) Separate O/Ps for each Compressor.
2) Temperature sensor.
3) Alarm relay o/p.
Alarms/ Protections1) Over Voltage protection set point user settable
2) Under Voltage protection set point user settable.
3) High/low temperature alarm set point user settable.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 3,800 / Piece Get Latest Price

Product Details:
Supply3 Phase 4 wire 415 V AC, 50Hz.
Display16 x 2 LCD Display for Status Faults.
SensorNTC Temp sensor 1 No for room temp. (Range 0 - 55 deg C)
Fire InputFire alarm input from fire panel
Dimensions330mm(W) X 220 mm (H) X 80 mm (O)
InputMCB TPN 32Amp, 10KA capacity.
Alarm OP5 Nos. Alarm contacts @ 7 Amp 250VAC.
MountingWall Mounting
Indications1) Healthy indication for controller. 2) A/C ON indication for Each A/C. 3) Alarm indications 5 Nos.
Output30 Amp single pole contactor for each A/C (230 V AC)

Technical Specifications:
Keys: 4 key keypad for settings1) SET Key: To enter into FUNCTION SET Mode/To view the next set pt.
2) Up Arrow Key: To increment the set point
3) Down Arrow Key: To decrement the set point.
4) ENTER Key: To come out of FUNCTION SET
Mode/To enter into menu/To accept the password
Sensing1. Inbuilt current sensing for compressor.
2. Temperature Sensing by precise Temp. Sensor.
3. Fire Alarm sensing.
Terminals1) Separate O/P s for each Compressor.
2) Temperature sensor.
3) Alarm relay o/p.
Alarms/ Protections1) Over load protection set point user settable.
2) Under load protection set point user settable.
3) High/low temperature alarm set point user settable.



Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 3,800 / Piece Get Latest Price

Product Details:
Fire inputFire alarm input from fire panel.
Alarm OP2 Nos. Alarm contacts @ 7Amp A/C.(250VAC)
SensorNTC Temp sensor for room Temp. (Range 0 - 55 deg C)
Output40Amp single pole contactor for each A/C (230VAC) for ALARM contact.
Supply3 Phase 4 wire 415 VAC, 50 Hz.
Display16*2 LCD Display for status Faults.
InputMCB TPN 32 Amp, 10 KA capacity.

Technical Specifications:
Indications1. Healthy indication for controller.
2. A/C ON indication for each A/C.
3.Alarm indication 2 no's: AC Alarm, Fire Alarm.
Front Panel1] 16 char. 2 lines LCD display with backlight.
2] 4 Key keypad for programming.
3] A/C1 ON indication.
4] A/C2 ON indication.
5] Healthy Indication by blinking Green LED.
6] ALARM indication by Red LED.
Terminals1] Separate O/Ps for each Relay.
2] Temperature sensor.
3] Fire Sensor.
4] Alarms relay o/p.
Alarms/ Protections1] Over Load protection set point user settable.
2] Under Load protection set point user settable.
3] High/low temperature alarm set point user settable.

Yes! I am Interested


Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Aux Supply48V DC
Input Supply Voltage230 VAC +- 15 %
Dimensions150 mm x 200 mm x 80(H x W x D)
Front Panel1) 16 char. 2 lines LCD display with backlit. 2) 5 Key keypad for programming.
Network Connectivity1) RS-485 Modbus RTU 2) LAN
OutputsFan : 0-10V DC Compressor : 230 VAC +- 15 Damper : 48V DC

Technical Specifications:
Sensing1) Inbuilt Voltage current sensing in Power
2) Temperature Sensing by precise temp. sensor.
3) Tacho input from Fan
4) High Pressure/Low Pressure sensing for compressor
Terminals1) Compressor Output
2) Damper Output.
3) Temperature sensor.
4) AC alarm relay o/p.
5) Room High alarm relay o/p.
6) Fan Supply Output (0-10V DC)
Alarms/ Protections1) OV/UV protection set point user Selectable.
2) OL/UL protection set point user Selectable.
3) High/low temperature alarm set point

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
ProtectionsOver voltage (OV): Cutoff 270 V Cut in 260 V Under voltage (UV): Cutoff 160 V Cut in 170 V
IndicationsA/C1 ON, A/C2 ON, ON Delay, Over voltage (OV) trip, Under voltage (UV) Trip, Manual Mode, Auto Mode.
Change over Time Delay4/8 Hr ( site selectable switch)
Dimension85(W) X 190 (L)
ON Delay Time2 minute 30 sec
Input Supply230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs.
OP ContactsO/P contact for both A/C 2
MountingWall Mounting
OP Contacts Rating30 amps At 230 VAC

Other Details:
Working1. If Auto/Man switch is in Auto mode Test/Timer switch is in Timer position then each A/C runs for Hrs. which is selected by user.
2. If Auto/Man switch is in Auto mode Test/Timer switch is in Test position then both A/C runs for Hrs. which is selected by user.
3. If Auto/Man switch is in Manual mode then A/C will be ON which is selected by third DIP switch. It will be continuously ON.




Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)

Yes! I am Interested
View PDF


Get Best Quote

Approx. Rs 2,500 / Piece Get Latest Price

Product Details:
System3 phase 4 wire 400 V AC, 50Hz +/- 15%.
Contact Rating3pole 16A contactor for compressor 25 Amp MCB for compressor outputs,
Temperature Sensing Range0.0 deg C to 50.0 deg C.
Temperature SensorThermistor Sensor NTC 10K @ 25 deg C Metal Body with Clamp.
IndicationsAC ON indication for AC1, AC2 and AC3 . Fault indication for AC1, AC2 and AC3.
Auxiliary PowerNo External power is required (Draws power from the voltage signal Inputs)
Frequency50 Hz / 60 Hz range (+-5 Hz)
Accuracy1] Volt 0.25% rdg +- 1 dgts.2] Current 0.25% rdg +- 1 dgts.
Environmental1] Working Temp : 0 to 55 deg C 2] Storage Temp : 10 to 70 deg C 3] Relative humidity : 0 - 95 %

Technical Specifications:
Measured Parameters1] Voltage (Volt) Phase - Phase measured. (RMS)
2] Unbalance Voltage measured Phase - Phase Unbalance measured.
3] Current (Amps) Compressor1, Compressor2, Heater, Blower (3Ph 4 w).
4] Room Temperature.
Protection1] Over Voltage Protection (Settable)
2] Under Voltage Protection (Settable).
3] Over Load Protection (Settable).
4] Under Load Protection (Settable).
5] Unbalance (Settable)
6] Reverse Phasing (Settable)
7] Phase Failure Protection (Settable)
8] High pressure (potential free input) (AC1/AC2)
9] Low pressure (potential free input) (AC1/AC2)
10] AHU Door Open (potential free input) (Blower/Master controller)
Communication Output1] Serial port : RS 485
2] Baud rate : Default: 9600
3] Start bit : 1
4] Stop bit : 1
5] Protocol : MODBUS - RTU

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Contact Rating30 A at 230 V AC for Compressor Live Outputs 5 A at 250V AC for Alarm Potential Free Outputs (C,N,O)
MountingWall Mounting
Temperature Sensing Range0.0 deg C to 55.0 deg C
Resolution1V for Voltage, 0.1 A for Current 0.1 deg C for temperature.
Temperature SensorThermistor Sensor NTC 10K@25 deg C Metal body with clamp Sensor Cable Length: 2.75 meters
Supply Voltage230 V AC, 50 Hz 15% separate phases for each A/C.

Technical Specifications:
Indications1) Supply ON for A/C1 A/C2, A/C3. Colour: Yellow
2)OV/UV Fault Colour: Red
3) Sensor Fail fault Colour: Red
4) Room temperature High fault Colour: Red
5) Healthy Colour: Green
6) Keys: 4 key keypad for settings. 1] SET Key : To enter into FUNCTION SET Mode/To view the next set pt. 2] Up Arrow Key : To increment the set point
3] Down Arrow Key: To decrement the set point.
4] ENTER Key: To come out of FUNCTION SET mode/To enter into menu/To
accept the password
7) Mounting : Wall mounting
8) Size : 245 mm (H) X 235 mm (W) X 67 mm (D

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
MountingWall Mounting
Resolution1V for Voltage, 0.1A for Current 0.1 deg C for temperature.
Dimensions245 mm (W) X 235 mm (H) X 67 mm (D)
Temperature Sensing Range0.0 deg C to 55.0 deg C
Supply Voltage230 V AC, 50 Hz +- 15% separate Phase for each A/C
Contact Rating30 A at 230 V AC for Compressor Live Outputs 7 A at 250 V AC for Alarm Potential Free Outputs C,N,O
Temperature SensorThermistor Sensor NTC 10K@25 deg C Metal body with clamp Sensor Cable Length: 2.75 meters

Technical Specifications:
Indications1] Supply ON for A/C1 A/C2, A/C3 A/C4. Colour: Yellow
2] OV/UV Fault Colour: Red
3] Sensor Fail fault Colour: Red
4] Room High fault Colour: Red
5] Healthy Colour: Green
Keys4 key keypad for settings. 1] SET Key: To enter into FUNCTION SET Mode/To view the next set point
2] Up Arrow Key: To increment the set point
3] Down Arrow Key: To decrement the set point.
4] ENTER Key: To come out of FUNCTION SET mode/To enter into menu/To accept the password.


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)

Yes! I am Interested


Get Best Quote

Approx. Rs 3,500 / Piece Get Latest Price

Product Details:
Supply Voltage(3P) 415 V AC, 50 Hz +/- 15% separate for each A/C.
Auto Controller Bypass SwitchTo bypass the controller i.e. A/C1 A/C2 will remain ON continuously if both the switches are in ON
Temperature Sensing Range0.0 deg C to 55.C deg
Resolution1V for Voltage, 0.1 A for Current 0.1 deg C for temperature.
Contact Rating(3P) 9A 3 Phase Contactor for Live outputs and 5A at 250 V AC for Alarm Potential Free Outputs(C,N,O
Temperature SensorThermistor Sensor NTC 10K@25 deg C Metal body with clamp. Sensor Cable Length: 2.75 meters

Technical Specifications:
Indications1) SupplyON for A/C1 A/C2. Colour: Yellow
2) Auto Mode for A/C1 A/C2 Colour: Green
3) Manual Mode for A/C1 A/C2 Colour: Red
4) AC ON for A/C1 A/C2 Colour: Green
5) Fault for for A/C1 A/C2 Colour: Red
6) Room High Colour: Red
7) Healthy Colour: Green
Keys4 key keypad for setting
1) Set Key
2)Up (Arrow )Key
3)Down( Arrow ) Key
4)Enter Key


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)

Yes! I am Interested
View PDF


REQUEST CALLBACK
Get Best Quote

Approx. Rs 3,800 / Piece Get Latest Price

Product Details:
Indications1.Healthy: Indicates controller is working healthy. 2. ALARM : when this LED glows it indicates some
Under VoltageDefault 180 V User settable by keys. 10 V hysteresis. Auto reset.
Under LoadDefault 3 A user settable. Make it 0 A to bypass UL protection
On TimeDefault 60 min. User settable by keys
Output Contact RatingOutput contact rating for AC 25 A at 230 VAC
Restart Delay Time3 minutes
Trip Time Delay3 sec for UV OV , 5 sec. OL 5 minutes for UL Low lube oil pressure Fire n alternator fault
Off TimeDefault 30 min. User settable by keys
Over VoltageDefault 260 V .User settable by keys. 10 V hysteresis between Cutoff Cut in. Auto reset
System Supply230 VAC +/- 15%
Power On Delay Time1 minutes
Over LoadDefault 15 A. User settable by keys.

We are offering AC Protector to our clients.


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)

Yes! I am Interested
View PDF


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Supply Voltage415 VAC +- 15 %( R, Y, B, N).
Mounting TypePanel Mount, Plug-In, DIN Rail
Current2 A,10 A,4 A,1 A,6 A,5 A
Output Contact Rating30 Amps. At 250 V AC for A/C contacts. 7 Amps. At 250 V AC for ALARM contact.

Technical Specifications:
Front Panel1)16 char. 2 lines LCD display with backlight.
2) 4 Key keypad for programming.
3) A/C1 ON indication.
4) A/C2 ON indication.
5) A/C3 ON indication.
6) A/C4 ON indication
7) A/C5 ON indication
8) A/C6 ON indication.
9) Healthy Indication by blinking Green LED.
10) ALARM indication by Red LED.
Sensing1)Inbuilt voltage sensing for compressor.
2) Temperature sensing by precise Temp. Sensor.
3) Fire Alarm sensing.
Terminals1) Separate O/Ps for each Compressor.
2) Temperature sensor.
3) Alarm relay o/p.
Alarms/ Protections1) Over voltage protection set point user settable.
2) Under voltage protection set point user settable.
3) High/low temperature alarm set point user settable

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Supply Voltage250 VAC +- 15 %
Alarms ProtectionsHigh Pressure/Low pressure Alarm. High/low temperature alarm set point user settable. AHU fault Alm.
Dimensions330mm(W) X 220 mm (H) X 80 mm (O)
Output Contact Rating30 Amps at 250 V contacts.

Technical Specifications:
Front Panel16 char. x 2 lines LCD display with backlight. 4 Key keypad for programming.
A/C1 ON indication.
A/C2 ON indication.
A/C3 ON indication.
A/C4 ON indication.
A/C5 ON indication.
A/C6 ON indication.
A/C7 ON indication.
Healthy Indication by Green LED.
ALARM indication by Red LED.
SensingHigh Pressure(HP)/ Low Pressure(LP) sensing for every AC.
Temperature sensing by precise Temp. Sensor.
AHU fault sensing.
TerminalsSeparate O/Ps for each Compressor
HP/LP input for each A/C.(It should be potential free)

Yes! I am Interested


Get Best Quote

Approx. Rs 3,500 / Piece Get Latest Price

Product Details:
Contact Rating30 A at 230 V AC for compressor Live Outputs 5 A at 250 V AC Alarm Potential free outputs(C, N/O)
Supply Voltage230V AC, 50 Hz +/- 15% separate for each A/C.
Temperature Sensing Range0 - 55 deg C
Temperature SensorThermistor sensor NTC 10K @ 25 deg C metal body with clamp. Sensor cable length 2.75 meters.

Technical Specifications:
Resolution1 V for voltage, 0.1 A for Current 0.1 degree C for Temperature.Auto/Controller Bypass Switch is used to bypass the controller i.e. A/C 1 A/C 2 will remains ON(irrespective of temperature demands) if both switches are in ON condition.

Yes! I am Interested


Get Best Quote

Approx. Rs 1,800 / Piece Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
Nominal Voltage Input1) Single Phase 230 V AC 2) Accuracy Range 50 - 115 % of nominal voltage.
Auxiliary PowerNo External power is required (Draws power from the voltage signal Inputs)
Frequency50 Hz / 60 Hz range (+-5 Hz)
Nominal Input Current5 Amp 1) Accuracy Range for 5 Amps = 120 % nominal.

Technical Specifications
Measured Parameters1) RMS Voltage (Volt) (R, Y, B Phase) Phase - Neutral measured.
2) RMS Current (Amps) (R, Y, B Phase) Phase current
3) Frequency (R, Y, B Phase)
4)Power Factor (R, Y, B Phase)
5) Active Power (KVA) (R, Y, B Phase)
6) Apparent Power (KW) (R, Y, B Phase)
7) Main's KWH
8) DG KWH
9) DG Run hour
10) Mains Run hour
Accuracy1) Volt 0.25% +- 1 dgts.
2) Current 0.25% +- 1 dgts.
3) Frequency 0.1% Hz +- 1 dgts.
4) Power Factor 0.25% +- 1 dgts. (for 0.5 Lag
- 1.0 - 0.8 Lead)
5) Active Power 0.5% +- 1 dgts.
6) Apparent Power 0.25% +- 1 dgts.
7) Active Energy Class 1.0
Communication Output1) Serial port RS 485
2) Baud rate Selectable 1200, 2400, 4800, 9600,
19200. (Default 9600)
3)No of Unit 1-32 (Default 1)
4) Start bit 1
5) Stop bit 1
6) Protocol MODBUS - RTU
7) Parity None
Environmental1) Working Temp 0 to 55 C
2) Storage Temp 10 to 70 C
3) Relative humidity 0 - 95 % non-condensive
4) Warm up time 30 Sec
Enclosure1) Mounting Panel mounting.
2) Position Panel.
3) Enclosure 96 X 96 X 110 mm.
4)Cutout 92 X 92 mm
5) Terminal Screw ON Terminals.

Yes! I am Interested


Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Supply Voltage230 VAC +- 15 % for Single Phase 415 VAC +- 15% for Three Phase Separate power supplies for each AC
Dimensions1) Controller : 245 mm X 150 mm X 60 mm 2)Power supply unit:-125mm X 68mm X168mm
Power Supply UnitFor 3PN 1 Ph Supply

Technical Specifications:
Output Contact RatingPer A/C1] Single Phase : a] 25 Amps. at 230 VAC for Compressor Output
b] 7Amps. at 230V AC for fan alarm outputs.
2] Three Phase : a] 9 Amps. at 230 VAC 3 Phase Contactor for Compressor Output
b] 7Amps. at 230V AC for fan alarm outputs.
Front Panel1) 16 char X 2 lines LCD display with backlit.
2) 4 Key keypad for programming.
3) Power indication for each AC.
4) AC ON indication for each AC
5) Controller Healthy Indication by Blinking Green LED
6) ALARM indication by Red LED.
Sensing1) Inbuilt Voltage Current sensing in Power supply unit for compressor.
2) Temperature Sensing by accurate Temp.sensor. 3) Fire Input Sensing
4) DG Mode Sensing
Terminals1) Power unit for each AC, separate o/ps for 2 Fans 2 Compressors.
2) Temperature sensor.
3) AC1 fail alarm relay o/p.
4) AC2 fail alarm relay o/p.
5) Power fail alarm relay o/p
Alarms/ Protections1) Over voltage protection set point user settable.
2) Under voltage protection set point user settable.
3) Over load protection set point user settable.
4) Under load protection set point user settable.
5) Automatic cut off for smoke/Fire.
6) High/low temperature alarm set point user selectable.


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)

Yes! I am Interested
View PDF


 






Corporate Brochure




 

 

Send SMS
Sai Enterprises
Ajith Kumar Nimbalkar  (Proprietor)
No. 107, 2nd Main, MEI Colony, Laggere Main Road, Peenya Industrial Area
Bengaluru - 560058 , Karnataka , India
Send E-mail
Share Us:
X