Sai Enterprises
Sai Enterprises
Peenya, Bengaluru, Karnataka
Send E-mail
Send SMS
Home  » Our Products  » 

MOTER CONTROLLER


Wholesale Trader of a wide range of products which include 4ac controller model: tt-4, mobile pump controller with starter, pump starter with automatic tank level control, mini pump starter unit with level water controller indicator and mobile pump controller without display.

REQUEST CALLBACK
Get Best Quote

Approx. Rs 4,000 / Piece Get Latest Price

Product Details:
Minimum Order Quantity1 Piece
Power30A
ConditionNew
Automatic GradeAutomatic
SupplySingle phase 230 VAC, 50 Hz.
Display16 x 2 LCD Display for status Faults.
Output30 Amps. At 250 V AC for A/C Contacts
Alarm OP2 Nos. Alarm contacts @ 7A 250V
SensorNTC Temp. Sensor for room temp (Range 0 - 55 deg C)
Fire AlarmFire Alarm input from Fire Panel
Dimensions330mm(W) X 220 mm (H) X 80 mm (O)

Technical Specifications:
Indications1) Healthy indication for controller.
2) A/C ON indication for each A/C.
3) Alarm indication 2 nos: AC Alarm, Fire Alarm
Front Panel1) 16 char. 2 lines LCD display with backlight.
2) Key keypad for programming.
3) A/C1 ON indication.
4) A/C2 ON indication.
5) A/C3 ON indication.
6) A/C4 ON indication.
7) Healthy Indication by blinking Green LED.
8) ALARM indication by Red LED.
9) FUN,INC,DEC,ENT keys for parameter setting.
Sensing1) Inbuilt Voltage sensing for compressor.
2) Temperature sensing by precise Temp. Sensor.
3) Fire Alarm sensing.
Terminals1) Separate O/Ps for each Compressor.
20 Temperature sensor.
3) Alarm relay o/p.
Alarms/ Protections1) Over Voltage protection set point user settable.
2) Under Voltage protection set point user settable.
3) High/low temperature alarm set point user settable.

Yes! I am Interested


Get Best Quote

Approx. Rs 2,800 / Piece Get Latest Price

Product Details:
Input Supply3 Phase 415 V, 50 HZ AC (3 Phase 3 wire)
Input Current0-18 A per phase.
Accuracy1) Voltage 0.25% +-1 dgts. 2) Current 0.25% +- 1 dgts.
Output Contact Rating18 A at 415 volt Contactor. , 7 A at 250 volt.
Auxiliary PowerNo External power is required (Draws power from the Voltage Inputs

Technical Specifications:
Environmental1) Working Temp : 0 to 55 Degree C
2) Storage Temp : 10 to 70 DegreeC
3) Relative humidity: 0 95 % non-condensive
4) Warm up time : 30 Sec
Enclosure1] Mounting : Surface mounting.
2) Type : Panel.
3) Enclosure : 275(W) X 185 (H) X 116(D) mm.
4) Terminal : Screw ON Terminals.
LEDs1) UV (RED): Under Voltage Fault.
2) OV (RED): Over Voltage Fault.
3) SPP/UB/RP (RED): SPP, Voltage Unbalance Reverse Phase Fault.
4) UL/CUB (RED): Under Load Current Unbalance Fault.
5) OL (RED): Over Load Fault.
6) Relay (Green): Supply Healthy (No fault)

Yes! I am Interested


Get Best Quote

Approx. Rs 3,000 / Piece Get Latest Price

Product Details:
Input Supply3 Phase 415 V, 50 HZ AC (3 Phase 3 wire)
Input Current0-18 A per phase
Display Accuracy1) Voltage 0.25%. 2] Current 0.25%.
Output contact Rating18 A at 415 volt Contactor.
Auxiliary PowerNo External power is required (Draws power from the voltage signal inputs)

Technical Specifications:
Environmental1) Working Temp : 0 to 55 degree C
2) Storage Temp : 10 to 70 degree C
3) Relative humidity: 095 % non-condensive
4) Warm up time : 30 Sec
Enclosure1) Mounting : Surface mounting.
2) Position : Panel.
3) Enclosure : 275 (W) X 210(H) X 125(D) mm.
4) Terminal : Screw ON Terminals.
5) Display : 7 Segment ,4 digit
LEDs1) UV (RED): Under Voltage Fault.
2) OV (RED): Over Voltage Fault.
3) SPP/UB/RP (RED): SPP, Voltage Unbalance Reverse Phase Fault.
4) UL/CUB (RED): Under Load Current Unbalance Fault.
5) OL (RED): Over Load Fault.
6) Relay (Green): Supply Healthy (No fault)

Yes! I am Interested


Get Best Quote

Approx. Rs 3,000 / Piece Get Latest Price

Product Details:
Supply Voltage1) 230 VAC +-15 % 2)HP 3)Curent
SensingIn Built Current Sensing.
Protections1) Overload protection. 2) Under load (DRYRUN) protection.

Technical Specifications:
Front Panel1) Relay ON indication with green LED
2) Fault Indication by Red LED.
3) Power ON/OFF Switch
4) Auto/ Manual Switch
Indications1) Pump ON (Blinking->Pump off, Steady->Pump On ).
2) Dry Run (Glow -> Dry Run Fault).
3) Over Load (Glow -> Over Load Fault ).
4) Upper tank Full (Blinking->Upper Tank Empty, Steady-> Upper Tank Full)
5) Lower Tank Empty( Blinking->Lower ,Steady-> Lower Tank Empty)

Yes! I am Interested


Get Best Quote

Approx. Rs 3,000 / Piece Get Latest Price

Product Details:
Power0.75
Frequency50 Hz
Voltage240 V AC

Technical Specifications:
Environmental1) Working Temp : 0 to 55 DegreeC
2) Storage Temp : 10 to 70 DegreeC
3) Relative humidity: 95 % non-condensive
4) Warm up time : 30 Sec
Enclosure1) Mounting : Surface mounting.
2) Type : Panel.
3) Enclosure : 100(W) X 190 (H) X 95(D) mm.
4) Terminal : Screw ON Terminals
LEDs1) UV (RED): Under Voltage Fault.
2) OV (RED): Over Voltage Fault.
3) SPP/UB/RP (RED): SPP, Voltage Unbalance Reverse Phase Fault.
4) UL/CUB (RED): Under Load Current Unbalance Fault.
5) OL (RED): Over Load Fault.
6) Relay (Green): Supply Healthy (No fault)

Yes! I am Interested


 






Corporate Brochure




 

 

Send SMS
Sai Enterprises
Ajith Kumar Nimbalkar  (Proprietor)
No. 107, 2nd Main, MEI Colony, Laggere Main Road, Peenya Industrial Area
Bengaluru - 560058 , Karnataka , India
Send E-mail
Share Us:
X