Get Best Quote
![]() |
Sai Enterprises
Peenya, Bengaluru, Karnataka GST No. 29AHRPA5654N1ZN |
Approx. Rs 18,000 / Piece Get Latest Price
Minimum Order Quantity | 1 Piece |
Automatic Grade | Automatic |
Power | 30A |
Condition | New |
Supply | Single phase 230 VAC, 50 Hz. |
Display | 16 x 2 LCD Display for status Faults. |
Output | 30 Amps. At 250 V AC for A/C Contacts |
Alarm OP | 2 Nos. Alarm contacts @ 7A 250V |
Sensor | NTC Temp. Sensor for room temp (Range 0 - 55 deg C) |
Fire Alarm | Fire Alarm input from Fire Panel |
Dimensions | 330mm(W) X 220 mm (H) X 80 mm (O) |
Indications | 1) Healthy indication for controller. 2) A/C ON indication for each A/C. 3) Alarm indication 2 nos: AC Alarm, Fire Alarm |
Front Panel | 1) 16 char. 2 lines LCD display with backlight. 2) Key keypad for programming. 3) A/C1 ON indication. 4) A/C2 ON indication. 5) A/C3 ON indication. 6) A/C4 ON indication. 7) Healthy Indication by blinking Green LED. 8) ALARM indication by Red LED. 9) FUN,INC,DEC,ENT keys for parameter setting. |
Sensing | 1) Inbuilt Voltage sensing for compressor. 2) Temperature sensing by precise Temp. Sensor. 3) Fire Alarm sensing. |
Terminals | 1) Separate O/Ps for each Compressor. 20 Temperature sensor. 3) Alarm relay o/p. |
Alarms/ Protections | 1) Over Voltage protection set point user settable. 2) Under Voltage protection set point user settable. 3) High/low temperature alarm set point user settable. |
Approx. Rs 15,000 / Piece Get Latest Price
Input Supply | 3 Phase 415 V, 50 HZ AC (3 Phase 3 wire) |
Input Current | 0-18 A per phase. |
Accuracy | 1) Voltage 0.25% +-1 dgts. 2) Current 0.25% +- 1 dgts. |
Output Contact Rating | 18 A at 415 volt Contactor. , 7 A at 250 volt. |
Auxiliary Power | No External power is required (Draws power from the Voltage Inputs |
Environmental | 1) Working Temp : 0 to 55 Degree C 2) Storage Temp : 10 to 70 DegreeC 3) Relative humidity: 0 95 % non-condensive 4) Warm up time : 30 Sec |
Enclosure | 1] Mounting : Surface mounting. 2) Type : Panel. 3) Enclosure : 275(W) X 185 (H) X 116(D) mm. 4) Terminal : Screw ON Terminals. |
LEDs | 1) UV (RED): Under Voltage Fault. 2) OV (RED): Over Voltage Fault. 3) SPP/UB/RP (RED): SPP, Voltage Unbalance Reverse Phase Fault. 4) UL/CUB (RED): Under Load Current Unbalance Fault. 5) OL (RED): Over Load Fault. 6) Relay (Green): Supply Healthy (No fault) |
Approx. Rs 8,000 / Piece Get Latest Price
Input Supply | 3 Phase 415 V, 50 HZ AC (3 Phase 3 wire) |
Input Current | 0-18 A per phase |
Display Accuracy | 1) Voltage 0.25%. 2] Current 0.25%. |
Output contact Rating | 18 A at 415 volt Contactor. |
Auxiliary Power | No External power is required (Draws power from the voltage signal inputs) |
Environmental | 1) Working Temp : 0 to 55 degree C 2) Storage Temp : 10 to 70 degree C 3) Relative humidity: 095 % non-condensive 4) Warm up time : 30 Sec |
Enclosure | 1) Mounting : Surface mounting. 2) Position : Panel. 3) Enclosure : 275 (W) X 210(H) X 125(D) mm. 4) Terminal : Screw ON Terminals. 5) Display : 7 Segment ,4 digit |
LEDs | 1) UV (RED): Under Voltage Fault. 2) OV (RED): Over Voltage Fault. 3) SPP/UB/RP (RED): SPP, Voltage Unbalance Reverse Phase Fault. 4) UL/CUB (RED): Under Load Current Unbalance Fault. 5) OL (RED): Over Load Fault. 6) Relay (Green): Supply Healthy (No fault) |
Approx. Rs 8,000 / Piece Get Latest Price
Supply Voltage | 1) 230 VAC +-15 % 2)HP 3)Curent |
Sensing | In Built Current Sensing. |
Protections | 1) Overload protection. 2) Under load (DRYRUN) protection. |
Front Panel | 1) Relay ON indication with green LED 2) Fault Indication by Red LED. 3) Power ON/OFF Switch 4) Auto/ Manual Switch |
Indications | 1) Pump ON (Blinking->Pump off, Steady->Pump On ). 2) Dry Run (Glow -> Dry Run Fault). 3) Over Load (Glow -> Over Load Fault ). 4) Upper tank Full (Blinking->Upper Tank Empty, Steady-> Upper Tank Full) 5) Lower Tank Empty( Blinking->Lower ,Steady-> Lower Tank Empty) |
Approx. Rs 5,000 / Piece Get Latest Price
Frequency | 50 Hz |
Voltage | 240 V AC |
Power | 0.75 |
Environmental | 1) Working Temp : 0 to 55 DegreeC 2) Storage Temp : 10 to 70 DegreeC 3) Relative humidity: 95 % non-condensive 4) Warm up time : 30 Sec |
Enclosure | 1) Mounting : Surface mounting. 2) Type : Panel. 3) Enclosure : 100(W) X 190 (H) X 95(D) mm. 4) Terminal : Screw ON Terminals |
LEDs | 1) UV (RED): Under Voltage Fault. 2) OV (RED): Over Voltage Fault. 3) SPP/UB/RP (RED): SPP, Voltage Unbalance Reverse Phase Fault. 4) UL/CUB (RED): Under Load Current Unbalance Fault. 5) OL (RED): Over Load Fault. 6) Relay (Green): Supply Healthy (No fault) |
Price on Request: Get Latest Price
Nominal Input Current | 30 A |
Accuracy | Current 0.25% +- 1 dgts. |
Resolution | Current 0.01 A Environmental:- 1] Working Temp : 0 to 55 deg C |
Storage Temp | 1. Working Temp 0 to 55 C 2. Storage Temp 10 to 70 C 3. Relative humidity 0 - 95 % Non-Condensing 4. Warm up time 10 Sec |
Enclosure | 1. Mounting Panel mounting. 2. Dimensions 165 (W) X 60 (L) X 115 (H). Cutout 182(H) X 92(W) . Enclosure 105 (W) X 200 (L) X 193 (H) mm. |
Terminal | WORKING In normal running mode, display shows 1. U-Voltage 2. C-Current 3. < Faults if any> - UV-Under Voltage - OV-Over Voltage - OL-Over Load - R-on AUTO-Relay on Auto |